Posted  by  admin

Invalid Inconsistent License Key Solidworks Torrent

  1. Invalid Inconsistent License Key Solidworks Torrent Free
  2. Solidworks Product Key

The SolidNetwork Licensing (SNL) system is an extremely useful way of distributing SOLIDWORKS licenses around your Network from a central server. However, if there is an issue with the way your system is configured you may receive the following message: “Could not obtain a license for SOLIDWORKS Standard, server node is down or not responding”. The reasons for this message can vary, although in basic terms the message is a simple one, it means your client machine can’t get a connection to the server.

If you’re still in the process of installing your SNL, check out our SNL installation tutorial. Otherwise try running through the following to diagnose and fix the “Could not obtain a license for SOLIDWORKS” error message.

Many college and high school students these days are lucky enough to have access to SOLIDWORKS in their classrooms and computer labs. This is a really great way to learn not only 3D CAD, but engineering and design principles in general. But did you know that if you are a student at a school that has. Mar 19, 2009. (AutoCAD, SolidWorks, DraftSight. INVALID(INCONSISTENT) LICENSE KEY OR SIGNATURE. Invalid license key (inconsistent.

Check the SNL service is running

The SNL service runs on the server and distributes the licenses to the separate client machines. However, if the service isn’t running (or has a problem) the system won’t function.

To Correct the problem, on the server press the windows key, and type “services”. Then open the Services application.

Key

From here you will find the SNL Manager, you can Stop, Start and Restart the service from here.

n.b. if other machines are using the SOLIDWORKS on the SNL they may lose connection if you do this. It’s a good idea to check first.

Check it’s the same version or greater

If SOLIDWORKS has recently been installed it may be at a different year version compared to the server. The SNL is backwards compatible, so can be newer in version than the clients. However, its not forwards compatible.

The following needs to be done on the server:

To check the version of the SNL, open the start menu and type SolidNetwork. You’ll see the sever application in the list. Click on this one, not the client.

Once this application is open, Click the ‘About…’ button in the bottom left. You will be presented with a version number. In above example the number is 26.1.

This means the install is 2018 SP1 (the easiest way to work this out is to take 8 from the version number, i.e. 26 – 8 = 18, so… 2018! the .1 is the service pack version).

If your SOLIDWORKS and SNL are at different versions refer to the following blog:

Don’t forget to activate the server again once you have upgraded!

Check the connection

You may be receiving the “Could not obtain a license…“error message because you cannot get a physical connection to the server. Here’s how to diagnose and test this:

Ping the server: Open the command prompt in windows (type cmd into the start menu). Once open type: Ping <server computer name>

You should receive a response, if not you know the problem is an issue in your network. Try and reconfigure some of your network architecture and try again.

Firewall ports

If you can get a connection to the sever, it may be the port used for SNL communication is blocked. The SNL predominantly uses TCP port 25734, but also uses 25735 and 25744 for certain applications.

If you’re running a firewall you can allow connection over these ports by putting in exceptions. In this case we will look at how to do this in windows firewall.

On the server, open the start menu and type in Firewall with Advanced security to find the application where this can be set. Open the application and click:

  1. Inbound Rule > New Rule…
  2. Select Port on the first screen, click next
  3. Select TCP and specific ports and enter “25734,25735,25744”, click Next
  4. Select Allow the connection, click Next
  5. Select Domain and Private
  6. Give the item a name you can recognise, like SOLIDWORKS SNL
  7. Repeat the same process on the client machine, but click Outbound Rule at step a.

Contact your SOLIDWORKS reseller

If you’re still unable to fix the issue and you have an annual subscription contract with your reseller, we recommend giving them a call for assistance. If you’re an Innova Systems customer you can contact us here.

We hope you found that useful!

Have you seen our blog archive where we have posted plenty of helpful articles? We also have a fantastic video library filled with easy-to-follow videos on a number of topics inspired by other SOLIDWORKS users – take a look. Also, don’t forget to follow Innova Systems on Twitter for daily bite size SOLIDWORKS tips, tricks and videos.

Issue:

You might see a serial number error while trying to activate a product for one of several reasons:

Solution:

You entered a typo

Invalid inconsistent license key solidworks torrent download

Try entering the values again in case you misspelled something.

  • The serial number is misspelled:
    • The serial number must have exactly 12 characters (11 numerals and a hyphen).
    • The serial number cannot contain alpha characters.
      See:Finding Serial Numbers & Product Keys
  • The company name must match the account name listed for the license.
  • The host name is incorrect (only valid for network licenses).
  • The machine address, physical address, or host ID is incorrect (only valid for network licenses).
  • The host ID is incorrect (only valid for network licenses. For more information, see How to find your Host Name and Physical Address.

Your serial number does not match the product

This error is often displayed as 'Serial Number is invalid.' There are several reasons why this mismatch can occur.

  • The serial number is valid but is associated with a different product (e.g., AutoCAD LT 2010 versus AutoCAD 2010).
  • The serial number is valid but is associated with a different version of AutoCAD (e.g., AutoCAD 2009 versus AutoCAD 2011).
  • The serial number is valid for a network deployment, but you are trying to activate the product as a stand-alone license (and vice versa).
Before registering and activating your license, make sure your serial number matches the product, release, and type of license you purchased. You can request a report that lists information about your product serial numbers, including product, version, and status, by visiting Contact Support - License Reports.

Your serial number is no longer valid

There are several reasons why a serial number may not be valid.

  • Your product might have been upgraded to a newer version or cross-graded to a different product.
  • The serial number is associated with a product or a release of a product that you are not licensed to use.
  • The serial number is obsolete and has been replaced with another serial number to simplify a contract.

Before registering and activating your product, make sure your serial number matches the product, release, and the type of license you purchased.
See:

You entered the serial number for an individual product rather than the collection serial number

If you are activating a product in a collection, make sure you use the serial number and product key for the collection (not the individual product). For more information, see Finding Serial Numbers & Product Keys.

You are trying to activate an ineligible previous version

You can only activate previous versions that are listed on the eligible previous version list for subscriptions or maintenance plans. For more information about when previous versions become ineligible for activation, see Product Support Lifecycle.

Your contact information doesn't match the serial number

Invalid Inconsistent License Key Solidworks Torrent Free

The contact information doesn't match what is already associated with the serial number when the product was registered. This can happen if there is a change to your name, the company name, or your address after the product was registered. Keep your contact information up-to-date using Register Once. There, you can add an account with your current information, register products to that account, and delete your old accounts, or those with outdated information.

You've exceeded the activation limit

Activation limits are based on the type of license agreement you have. They are designed to remain compliant with your license and protect you from someone else using your license. (You may receive 'Error 10: Activation Limit Reached' during the in-product activation process.)

  • If you have a stand-alone license, you might be able to transfer a license to activate this product. See: Using the License Transfer Utility to Transfer Licenses Online

    Otherwise, visit AVA (Autodesk Virtual Agent) to resolve the issue and automatically receive an activation code or connect with an agent. Provide your serial number, request code, and contact information

  • If you have a network license, contact Customer Support.

See Also:

Invalid Inconsistent License Key Solidworks Torrent
Want to know more about your license?Still having trouble activating?

Products:

3ds Max Design; Alias Automotive; AutoCAD Design Suite; AutoCAD; AutoCAD Architecture; Civil 3D; AutoCAD Electrical; AutoCAD LT; AutoCAD Map 3D; AutoCAD Mechanical; AutoCAD MEP; AutoCAD P&ID; AutoCAD Raster Design; Revit;

Solidworks Product Key

Versions:

2017; 2008; 2009; 2010; 2011; 2012; 2013; 2014; 2015; 2016; 2018;